# Controlled agent password autofill
Administrators separately approve `vault:status`, `vault:list` and `vault:fill`
in signed baseline policy and the individual grant. All start unchecked. Password
manager enablement, feature visibility/locks, autofill policy, user-profile rules,
actor destination scope, expiry and targeted revocation remain enforced.
| Action | Arguments | Output |
| --- | --- | --- |
| `vault:status` | Optional native `sessionId` | exists, locked, enabled and allowAutofill booleans |
| `vault:list` | Optional native `sessionId` | Up to 32 opaque credential references and approved HTTPS origins |
| `vault:fill` | Native `sessionId`, returned `credentialRef` | completed boolean |
The user creates or unlocks the vault through the trusted browser interface.
Agents cannot unlock, create, export, save, delete or retrieve plaintext passwords.
Inventory excludes usernames, labels, underlying record IDs and passwords. Origin
metadata passes the same local/enterprise inspection pipeline before export.
References expire after 60 seconds, are consumed once and are bound to actor,
policy, exact native tab/WebContents, context and private vault generation.
The reference pool is bounded at 32; this is not a complete paginated vault manager.
For filling, keep the target login tab visible and request a fresh inventory after
unlock. Use its reference only at the saved exact HTTPS origin. A single visible
same-origin, same-window POST login form is required. Visual protection, foreground
identity, policy, cancellation and lock state are checked again after waits.
Passwords pass only into the fixed isolated-world fill script. No arbitrary
selector, password value or script is accepted from the agent. Filling does not
submit the form, and a failed response never implies undo or authorizes a retry.
Tab changes and policy updates already lock the vault. Unlock again through the
trusted UI and refresh references after either event. Lock/reopen and mutation
attempts advance a private process-local generation; even a same-ID password
replacement invalidates older references. Status/inventory polling does not renew
the idle unlock deadline. This generation never appears in public responses.
Durable audit records pre-execution and completed/failed agent actions with verified
principal attribution, plus vault fill-requested/filled lifecycle events. Ordinary
audit, SIEM and diagnostic spans contain no credential values, references or native
record IDs. Debug spans separately name inventory inspection, visual authorization
and native fill under the protected RPC action.
Actual Windows/Electron proof uses a controlled HTTPS receiver with trust pinned
to its exact synthetic certificate in the isolated test session. It verifies human
unlock, real field filling, zero submitted requests, host filtering, actor/ref
boundaries, replay, relock/reopen, password replacement, central autofill disable,
targeted revocation and named exported OTLP phases. It does not prove production
certificate deployment or successful login submission. The separate tab-binding
unit test holds the vault unlocked to verify binding independently of automatic
tab-change locking (`artifacts/vault-agent-controls-native-proof.json`).
Outbound DLP still scans a later form submission. A credential matching a secret
rule can therefore block an otherwise legitimate login; there is no generic
password-field exception. A future governed allowance must bind one exact
submission and inspect every remaining field. Persistent sessions, file/vault
mutations, safe screenshots, broader administration and production key custody
remain separate open requirements.